Copyright 2024 by Rex Instruments
 
 
| Cancel
ProComSol develops HART communicators for mobile device software that bridges the gap between HART Protocol devices, allowing for configuration, monitoring, calibrating, and troubleshooting of HART instruments in industrial plants.
Mobile :: Brands Masthead
KELLER Series 21PY Pressure Transmitter

KELLER Series 21PY Pressure Transmitter

Product Description

 
 
 
   
 
The compact pressure transmitters of the 21PY series with 0,5...4,5V output have a diameter of just 15 mm and weigh in at less than 20 g. The sophisticated compensation circuit makes it possible to specify a narrow total error band.
 
The circuit is based on the PromComp principle which KELLER offered in a separate version as a laboratory device 20 years ago when it attained accuracy of 0,1 %FS over a temperature range of 100 Kelvin (K). In those days the electronic circuitry was the size of a cigar box, but now it can be accommodated on a print that is a mere 12 mm in diameter. Although this digital component is only slightly more expensive to produce than a pure analog circuit, it allows a piezoresistive sensor to be calibrated to an accuracy of 0,5 %FS over a potential temperature range of 100 K.
 
A temperature sensor divides the temperature range into fields with a width of 1,5 K each. Two values are assigned to each field in an EEPROM: one value for the zero point and another for the amplification, determined by mathematical interpolation in the calibration process. During operation, the corresponding values are ‚switched in’ at the relevant temperatures. The electronics make it possible to assign up to 120 fields so that a temperature range of 180 K can be covered. The 100 K restriction for series 21 PY is due to the sensor.
 
TThe 21 PY product line is outstanding due to its extreme ruggedness towards electromagnetic fields. The limits of the CE standard are undercut by a factor of up to 10 with conducted and radiated fields, thus making this product ideal for use in harsh industrial environments.
  • Pressure Ranges 0…10 to 0…600 bar
  • Accuracy ±0,25 %FS
  • Total Error Band ±0,7 %FS @ -10…80 °C
  • Interfaces 0,5…4,5 V
  • Temperature Range -20…100 °C
  • Homologation None
 
 
 
 
 
 
Copyright 2024 by Rex Instruments
Google Site Search