Copyright 2024 by Rex Instruments
 
 
| Cancel
ProComSol develops HART communicators for mobile device software that bridges the gap between HART Protocol devices, allowing for configuration, monitoring, calibrating, and troubleshooting of HART instruments in industrial plants.
Mobile :: Brands Masthead
PIE 422 14-Type Thermocouple Calibrator

PIE 422 14-Type Thermocouple Calibrator

Product Description

 
 
 
   
 
  • Automatic Stepping & Ramping
  • Larger Display with Backlight
    Easy viewing in dark locations
  • More Resistant to Accidental Damage
    Rubber Boot and Stronger Switches
  • Separate Battery Compartment
    No more removing housing with screwdriver to replace batteries
    Calibration seals remain intact
  • More Accurate and Repeatable
    NIST Traceable Cold Junction Sensor in isothermal block
  • Easily Change Thermocouple Types
    Reconfigure without resetting calibrator
  • Verify Cold Junction Temperature & Output
    Secondary display of compensated millivolt setting and cold junction temperature
  • Includes Certificate of Calibration
    All PIE Calibrators come with a free signed and dated certificate. Altek’s come only with an unsigned Statement of Calibration Practices with a certificate of calibration available for an extra charge.
 
 
 
 
 
 
 
  • Calibrate Milliamp Instruments
    Source 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA
    Read 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA
    Read -60.00 to +60.00 VDC
    Simulate 2-Wire Transmitter, Power & Read Transmitters
    Menu Selectable 250 Ohm resistor for HART compatibility
  • Calibrate with Lab Accuracy
    Accurate to ±(0.01% of Reading + 0.002 mA)
    PIE 434 is more accurate than similar calibrators – within ±0.004 mA at 20 mA output!
  • Easy-to-Read Backlit Display
  • Locate Loop Current Leakages
    Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring.
  • Faster Calibrations
    Three output EZ-CHECK switch
    2 speed EZ-DIAL
    Stepping & Ramping
  • Includes Rubber Boot, Deluxe Hands Free Carrying Case & Test Leads
  • Optional Accessories
    AC Adaptor 120 V (020-0101); 240 V (020-0100)
    NiMh Batteries & Charger 120 VAC/12V DC (020-0103)
    Magnetic hanging strap(020-0236)

 

 
 
 
 
 
 
Copyright 2024 by Rex Instruments
Google Site Search